| Shot | Target | Backlighter | Shock beam | Backlighter beam | Pulse | Camera sweep | Camera delay | Comments
|
|---|
| | | | (J) | (ns) | (ns) | (ns) |
|
|---|
| 1 Aug
|
|---|
| 13567 | - | Au disc
| 0 | 33 | 1.8 (fence) | - | -
| X-ray camera timing (no signal)
|
| 13568 | - | Au disc
| 0 | 25 | 1.8 (fence) | - | -
| X-ray camera timing
|
| 2 Aug
|
|---|
| 13571 | - | Au disc
| 0 | 65 | 1.8 (fence) | - | -
| X-ray camera timing
|
| 13576? | - | Au disc
| 0 | 12 | ? | - | -
| X-ray camera timing (log for 13676)
|
| 13577 | - | Au disc
| 0 | 9 | 1.8 (fence) | - | -
| X-ray camera timing
|
| 13578 | - | Au disc
| 0 | 9 | 1.8 (fence) | - | -
| X-ray camera timing
|
| 13579 | - | Au disc
| 0 | 11 | 1.8 (fence) | - | -
| X-ray camera timing
|
| 13580 | - | Au disc
| 0 | 17 | 1.8 (fence) | - | -
| X-ray camera timing
|
| 13581 | - | Ti disc, 25 µm
| 0 | 101 | 1.8 | - | -
| Backlighter test
|
| 6 Aug
|
|---|
| 13583 | - | Mn, 12.5 µm
| 0 | 126 | 1.8 | - | -
| Backlighter test
|
| 13584 | - | Mn, 12.5 µm
| 0 | 166 | 1.8 | - | -
| Backlighter test
|
| 13585 | - | Mn, 12.5 µm
| 0 | 180 | 1.8 | - | -
| Backlighter test
|
| 13586 | - | Mn, 12.5 µm
| 0 | 181 | 1.8 | - | -
| Backlighter test
|
| 13587 | - | Ti, 6 µm
| 0 | 259 | 1.8 | - | -
| Backlighter test
|
| 7 Aug
|
|---|
| 13609 | - | Ti, 6 µm
| 0 | 259 | 1.8 | - | -
| Backlighter test
|
| 13610 | - | Mn, 12.5 µm
| 0 | 272 | 1.8 | - | -
| Backlighter test
|
| 13611 | Si | Mn, 12.5 µm
| 0 | 274 | 1.8 | - | -
| Static TXD; re-usable holder.
|
| 13612 | Cu, 110 µm | -
| 88 | 0 | 1.8 | - | -
| VISAR test
|
| 8 Aug
|
|---|
| 13614 | Cu, 110 µm | -
| 79 | 0 | 1.8 | - | -
| VISAR test
|
| 13615 | - | V
| 0 | 269 | 1.8 | - | -
| Backlighter test
|
| 13616 | - | V
| 0 | 243 | 1.8 | - | -
| Backlighter test
|
| 9 Aug
|
|---|
| 13618 | - | Mn, 6 µm
| 0 | 266 | 1.8 | - | -
| Backlighter test
|
| 13619 | Cu 001 crystal, 2 µm | Ti, 6 µm
| 0 | 262 | 1.8 | - | -
| Static TXD, re-usable holder. Crystal glued to brass support.
|
| 13620 | Au, 25 µm | -
| 61 | 0 | 1.8 | - | -
|
|
| 13 Aug
|
|---|
| 13623 | Cu 001 crystal, 2 µm | Ti, 6 µm
| 0 | 240 | 1.8 | - | -
| Static TXD, Ta knife-edge attached with epoxy, re-usable holder.
Crystal glued to brass support.
|
| 13624 | Au, 25 µm | -
| 87 | 0 | 1.8 | - | -
|
|
| 13625 | Si 001 crystal | Mn, 12.5 µm
| 49 | 234 | 1.8 | - | -
| Dynamic TXD, TFF assembly.
|
| 13626 | Si 001 | -
| 52 | 0 | 1.8 | - | -
| Probe laser didn't fire.
|
| 14 Aug
|
|---|
| 13628 | Si 001 crystal | Mn, 12.5 µm
| 130 | 241 | 1.8 | - | -
| Dynamic TXD, TFF assembly.
|
| 13629 | Cu 001 crystal, 8 µm | Ti, 6 µm
| 0 | 249 | 1.8 | - | -
| Static TXD, Ta knife-edge attached with epoxy, re-usable holder.
Crystal glued to brass support.
|
| 13630 | Au, 25 µm | -
| 99 | 0 | 1.8 | - | -
|
|
| 13631 | Si 001, half-aluminised | -
| 137 | 0 | 1.8 | - | -
|
|
| 13632 | Cu 001 crystal, 8 µm | Ti, 6 µm
| 0 | 184 | 1.8 | - | -
| Static TXD, Ta knife-edge attached with epoxy, re-usable holder.
Crystal glued to brass support.
|
| 15 Aug
|
|---|
| 13634 | Si 001 | -
| 148 | 0 | 1.8 | - | -
|
|
| 13635 | Cu 001 crystal, 8 µm | Ti, 6 µm
| 0 | 254 | 1.8 | - | -
| Static TXD, Ta knife-edge attached with epoxy, re-usable holder.
Crystal glued to brass support.
|
| 13636 | Au, 25(?) µm | -
| 212 | 0 | 1.8 | - | -
|
|
| 13637 | Cu 001 crystal, 8 µm | Ti, 6 µm
| 18 | 225 | 1.8 | - | -
| Dynamic TXD, Ta knife-edge attached with epoxy, re-usable holder.
Crystal glued to brass support. (Sample fired statically in 13635.)
|
| 13639 | Si 001 (half aluminised) | -
| 176 | 0 | 1.8 | - | -
|
|
| 13640 | Si 001 crystal | Mn, 12.5 µm
| 80 | 235 | 1.8 | - | -
| Dynamic TXD.
|
| 13641 | Au, 25(?) µm | -
| 151 | 0 | 1.8 | - | -
|
|
| 13642 | Cu 001 crystal, 8 µm | Ti, 6 µm
| 0 | 261 | 1.8 | - | -
| Static TXD, Ta knife-edge attached with epoxy, re-usable holder.
Crystal glued to brass support.
|
| 16 Aug
|
|---|
| 13644 | Au, 25 µm | -
| 216 | 0 | 1.8 | - | -
|
|
| 13645 | Cu 001 crystal, 8 µm | Ti, 6 µm
| 30 | 246 | 1.8 | - | -
| Dynamic TXD, Ta knife-edge attached with epoxy, re-usable holder.
Crystal glued to brass support. (Sample fired statically in 13642.)
|
| 13646 | Au, 25 µm | -
| 195 | 0 | 0.9 | - | -
|
|
| 13647 | Cu 001 crystal, 8 µm | Ti, 6 µm
| 26 | 239 | 1.8 | - | -
| Dynamic TXD, Ta knife-edge attached with epoxy, re-usable holder.
Crystal glued to brass support.
(Possibly Be foil instead - check notes!)
|
| 13648 | Cu 001 crystal, 8 µm | Ti, 6 µm
| 0 | 245 | 1.8 | - | -
| Static TXD, Ta knife-edge attached with epoxy, re-usable holder.
Crystal glued to brass support.
|
| 13649 | Au, 25 µm | -
| 181 | 0 | 0.7 | - | -
|
|
| 13650 | Cu 001 crystal, 8 µm | Ti, 6 µm
| 28 | 228 | 1.8 | - | -
| Dynamic TXD, Ta knife-edge attached with epoxy, re-usable holder.
Crystal glued to brass support. (Sample fired statically in 13648.)
|
| 13651 | Ga crystal, ~100 µm | -
| 99 | 0 | 2.33 | - | -
|
|
| 20 Aug
|
|---|
| 13653 | Si 001 crystal | Mn, 12.5 µm
| 71 | 268 | 1.8 | - | -
| Dynamic TXD.
|
| 13654 | Ga crystal, 103 µm (sample 7) | -
| 42 | 0 | 1.8 | - | -
|
|
| 13655 | Be, 125(?) µm | Ti, 6 µm
| 63 | 261 | 1.8 | - | -
| Dynamic polycrystal TXD, re-usable holder, collimator.
|
| 13656 | Ga crystal, 93 µm | -
| 80 | 0 | 1.8 | - | -
|
|
| 13657 | Be, 125 µm | Ti, 6 µm
| 150 | 178 | 1.8 | - | -
| Dynamic polycrystal TXD, re-usable holder, collimator.
|
| 21 Aug
|
|---|
| 13662 | Be, 125 µm | Ti, 6 µm
| 0 | 241 | 1.8 | - | -
| Static polycrystal TXD, re-usable holder, collimator.
|
| 13663 | Ti, 25.4 µm | -
| 38 | 0 | 1.8 | - | -
|
|
| 13664 | Be, 125 µm | Ti, 6 µm
| 0 | 235 | 1.8 | - | -
| Static polycrystal TXD, re-usable holder, collimator.
|
| 13665 | Ti, 25.4 µm, + LSO crystal, ~50 µm | -
| 37 | 0 | 1.8 | - | -
|
|
| 22 Aug
|
|---|
| 13667 | Ga crystal, 60 µm | -
| 153 | 0 | 1.8 | - | -
|
|
| 13668 | Ga crystal, 60 µm | -
| 73 | 0 | 1.8 | - | -
|
|
| 13669 | Ga crystal, 60 µm | -
| 43 | 0 | 1.8 | - | -
|
|
| 13670 | Be, 50 µm | -
| 216 | 0 | 1.8 | - | -
|
|
| 13671 | Si 001, 40 µm (half aluminised) | -
| 47.8 | 0 | 1.8 | - | -
|
|
| 13672 | Be, 25 µm | -
| 211 | 0 | 0.9 | - | -
| Nominal 3 mm drive spot (unsmoothed). Shorter etalon in VISAR.
|
| 23 Aug
|
|---|
| 13673 | Be, 25 µm | Ti, 6 µm
| 0 | 147 | 2.0 | - | -
| Static polycrystal TXD, re-usable holder, collimator.
|
| 13674 | Be, 25 µm | Ti, 6 µm
| 0 | 103 | 2.0 | - | -
| Static polycrystal TXD, re-usable holder, collimator.
|